1kVA 110V 60Hz to 220V 50Hz Converter

1 kVA single phase 110V 60Hz to 220V 50Hz frequency converter, static pure sine wave output, make home appliances rated at 220V 50Hz (e.g. China) working better at 110V 60Hz (e.g. US) power supply.
Delivery date: 6 - 12 days
$1,658.00
$1,351.64

1kVA static pure sine wave frequency converter, convert single phase 110V 60Hz power to 220V 50Hz power in one step by inner step-up transformer. To change 220V 50Hz to 110V 60Hz, we have another converter with a little cheaper price, see more...

Specification

Model HZ-60-1101
Capacity 1 kVA
Dimension 510*430*200mm
Weight 45 kg
Input Voltage 1 Phase 2 Wire: 110V/120V ± 10%
Frequency 50Hz, 60Hz or 400Hz ± 5%
Output Voltage, current 110V Setting (Low grade): 0-150V, 8.4A
220V Setting 0-300V (High grade): 0-300V, 4.2A
Load stabilization Rate ≤±1%
Frequency 50Hz, 60Hz up to 400Hz adjustable
Frequency Stability ≤±0.01%
Harmonic Distortion Pure Sine Wave ≤2%
Frequency meter 4 digit, digital frequency meter, resolution 0.1Hz/Step
Voltmeter 4 digit, digital voltage meter, resolution 0.1V
Ammeter 4 digit, digital ammeter, resolution 0.1A
Watt meter 4 digit, digital Watt meter, resolution 0.1W
Protection With overload, short circuit, over temperature
Instantaneous power failure protection and alarm device
Working Environment Temperature 0 - 40 deg.℃
Humidity 0 - 90% (Non condensation)
Warranty 18 months

 

Tips: which is better, 110V 60Hz or 220V 50Hz power supplies?
Some where I read that the major reason of using 50Hz rather than 60Hz is the climate temperature is higher and high frequency can heat up wiring. In the area where the temperature is low, but can not change the power frequency to 60Hz due to we need to change the standards of all electrical equipment. Personally I don't think the temperature is a major concern for the grid frequency, think about Philippines (60Hz, 220V), China (50Hz, 220V), USA (60Hz, 110V), Canada (60Hz, 110V) and most European countries are 50Hz, that's the history factor.

The frequency of 50Hz need the voltage of 220V-240V and frequency of 60Hz needs less voltage 110V-120V. The countries like Canada, US are using 60Hz 110V power supplies. So that all the appliances that use electricity require to maintain standards of 60Hz 110V. The major harm of 50Hz is that the AC power supply with 220V-240V can harmful to human. But the 60Hz supply with 110V-120V has less harmful for human.