Cheap price 200 hp soft starter, 150 kW three phase 220v, 420v, 480v, 690v softstarter, control AC induction motor in soft start & soft stop, buy from China manufacturer directly.
Free shipping
Delivery date: 6 - 12 Days
-
-
-
-
$1,529.00
$1,379.53
200 hp AC motor soft starter, 150 kW three phase 220v, 420v, 480v, 690v motor starter.
Model |
GS2-150 (220v), GS3-150 (420v), GS4-150 (480v), GS6-150 (690v). |
Capacity |
200 hp (150 kw) |
Current |
300 amps at 380v/480v, 600 amps at 220v |
Weight |
21 kgs |
Dimension |
525*257*194 mm |
Input |
Voltage |
3 phase 220v, 420v, 480v, 690v AC |
Frequency |
50Hz/ 60Hz |
Adaptive Motor |
Squirrel-cage three-phase asynchronous motor |
Starting Times |
It is recommended not to exceed 20 times per hour. |
Communication |
DB9 interface, male plug, ① is RS485+, ⑥ is RS485- |
Control Mode |
(1) Operation panel control. (2) Operation panel + external control. (3) External control. (4) External control + COM control. (5) Operation panel + external + COM control. (6) Operation panel + COM control. (7) COM control. (8) No start or stop operation. |
Start Mode |
(1) Current-limiting to start. (2) Voltage ramp to start. (3) Torque control + current-limiting to start. (4) Torque control + voltage ramp to start. (5) Current ramp to start. (6) Voltage current-limiting double closed-loop start. |
Stop Mode |
(1) Soft stop. (2) Free stop. |
Protective Function |
(1) Open loop protection for external instantaneous stop terminals. (2) Over-heat protection for soft starter. (3) Protection for too long starting time. (4) Input open phase protection. (5) Output open phase protection. (6) Unbalanced three-phase protection. (7) Starting over current protection. (8) Running overload protection. (9) Under voltage protection for power voltage. (10) Overvoltage protection for power voltage. (11) Protection for fault parameter setting of the soft starter. (12) Load short circuit protection. (13) Auto restart or incorrect wiring protection. (14) Incorrect wiring protection of external control stop terminals. |
Ambient |
Place to be used |
Indoor location with good ventilation free from corrosive gas and conductive dust. |
Altitude |
Below 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M. |
Temperature |
-30 +55 oC |
Humidity |
90%RH without dew condensation. |
Vibration |
<0.5G |
Structure |
Enclosure |
IP 20 |
Cooling |
Natural wind cooling. |
Existing reviews
Please'd like to know the time of delivery of this equipment.
Bests Regards
By
Claudio
on 08/04, 2015
Was this review helpful?
Yes /
No
(0/0)