15 hp (11kW) VFD, 3 Phase 230V, 415V, 480V

Inexpensive 15 hp (11 kW) VFD, three phase 230V/415V/480V, high performance variable frequency drive, RS485 enabled, brand new direct sale by manufacturer in China.
Free shipping
Delivery date: 6 - 12 Days
$679.00
$634.44

15 hp (11 kW) variable frequency drive with good performance, three phase 230V, 415V, 480V for selection.

Specification:

Basics Model GK3000-4T0110G/ GK3000-2T0075G
Capacity 15 hp (11 kW)
Shipping weight 11 kg
Dimension 339*231*214 mm
I/O Feature Rated current 25A at 380V ~ 480V, 45A at 220V ~ 240V
Input voltage 3 phase 230V /415V /480V AC ±15% (Optional)
Input frequency 50Hz/ 60Hz
Output voltage 3 phase AC 0~input voltage
Output frequency 0.00~400.00Hz
Over load capacity 150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control Feature Control mode V/F control;
Sensorless vector control;
Communication RS485
Speed regulation 1:100
Start torque 150% of rating torque at 1 Hz
Speed control accuracy ≤±0.5% of rating synchronous speed
Frequency precision Digital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolution Analog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boost Automatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controller Be convenient to make closed-loop system
Automatic energy save running Optimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR) Can keep constant output voltage when power source voltage varies.
Automatic current limiting Limit running current automatically to avoid frequent over-current which will cause trip
Environment Enclosure rating IP 20
Temperature –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity 5%-95%, without condensation
Altitude ≤1000m; VFD will be derated if above 1000m
Impingement and oscillation Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

 

Tips: What's the lowest & highest frequency that a VFD can run?
This depends on what variable frequency drive (VFD) and what inverter you are using, most inverters will give you 0 Hz – 400 Hz frequency. However this must be matched by the VFD if your manufacturer has only rated and balanced the VFD to 50 Hz – 60 Hz then running it at 400 Hz would be catastrophic, similarly that same VFD wont enjoy low speeds of 15 Hz.

The normal operation depends on you process requirement, if your process requires 120 Hz then that's your normal operating speed, you may need to compensate for high torque in the process or ambient temperatures, these things can be factors in the actual speed you get in the control process.

Write your own review for 15 hp (11kW) VFD, 3 Phase 230V, 415V, 480V