Economic 300 hp (220 kW) variable frequency drive (VFD) for energy savings, vary motor speed and make motor in soft starting to avoid inrush current.
Free shipping
Delivery date: 6 - 12 Days
-
-
$12,199.00
$9,813.41
300 hp VFD, 220 kW VFD option for 240V, 415V, 460V etc.
Specification:
| Basics |
Model |
GK3000-4T2200G/ GK3000-2T2200G |
| Capacity |
300 hp (220 kW) |
| Shipping weight |
180 kg |
| Dimension |
1440*600*399 mm |
| I/O Feature |
Rated current |
426A at 380V ~ 480V, 820A at 220V ~ 240V |
| Input voltage |
Three phase 240V /415V /460V AC ±15% (Optional) |
| Input frequency |
50Hz/ 60Hz |
| Output voltage |
Three phase AC 0~input voltage |
| Output frequency |
0.00~400.00Hz |
| Over load capacity |
150 % of rated current for 1 minute, 200 % of rated current for 1 seconds |
| Control Feature |
Control mode |
V/F control; Sensorless vector control; |
| Communication |
RS485 |
| Speed regulation |
1:100 |
| Start torque |
150% of rating torque at 1 Hz |
| Speed control accuracy |
≤±0.5% of rating synchronous speed |
| Frequency precision |
Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% |
| Frequency resolution |
Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz |
| Torque boost |
Automatic torque boost, manual torque boost 0.1%~30.0% |
| Interior PID controller |
Be convenient to make closed-loop system |
| Automatic energy save running |
Optimize V/F curve automatically based on the load to realize power save running |
| Automatic voltage regulation (AVR) |
Can keep constant output voltage when power source voltage varies. |
| Automatic current limiting |
Limit running current automatically to avoid frequent over-current which will cause trip |
| Environment |
Enclosure rating |
IP 20 |
| Temperature |
–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5% |
| Humidity |
5%-95%, without condensation |
| Altitude |
≤1000m; VFD will be derated if above 1000m |
| Impingement and oscillation |
Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g) |
| Store environment |
–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight |
Tips: Benefits of Variable Frequency Drive over Star/Delta starting
On variable torque loads, power has a squared/cubed relationship to speed, so running the load at 60% speed requires between 21% and 36% of the power to run at 100% speed. On constant torque loads, power is directly proportional to speed, so 50% speed only requires 50% power. There are significant energy savings to be realized. Variable frequency drives (VFDs) also offer a soft start delivering 150 - 200% FLT at 0 to full speed with excellent current control so there are no hard start inrush current starts, particularly needed on weak power systems. Star/Delta starting is a reduced voltage method, unfortunately this also reduces torque in a squared relationship and therefore still allows 300 - 600% FL current, with resultant system voltage dips if network regulation is poor. No reduced voltage start method can compare with a VFD which maintains maximum motor air gap flux in a constant ratio of V/Hz, hence low current, high torque. Even soft starters (also reduced voltage method) are inferior if high dynamic torque control is needed.