60 hp (45 kW) VFD, 3 Phase 240V, 380V, 480V

Low price 60 hp (45 kW) VFD, three phase 240V, 380V, 480V energy saving variable frequency drive with high performance, brand new direct sale by Chinese manufacturer with fast delivery.
Free shipping
Delivery date: 6 - 12 Days
$2,569.70
$2,193.10

60 hp (45 kW) high quality variable frequency drive, three phase 240V, 380V, 480V for selection.

Specification:

Basics Model GK3000-4T0450G/ GK3000-2T0450G
Capacity 60 hp (45 kW)
Shipping weight 40 kg
Dimension 560*320*269 mm
I/O Feature Rated current 91A at 380V ~ 480V, 176A at 220V ~ 240V
Input voltage 3 phase 240V /380V /480V AC ±15% (Optional)
Input frequency 50Hz/ 60Hz
Output voltage 3 phase AC 0~input voltage
Output frequency 0.00~400.00Hz
Over load capacity 150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control Feature Control mode V/F control;
Sensorless vector control;
Communication RS485
Speed regulation 1:100
Start torque 150% of rating torque at 1 Hz
Speed control accuracy ≤±0.5% of rating synchronous speed
Frequency precision Digital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolution Analog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boost Automatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controller Be convenient to make closed-loop system
Automatic energy save running Optimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR) Can keep constant output voltage when power source voltage varies.
Automatic current limiting Limit running current automatically to avoid frequent over-current which will cause trip
Environment Enclosure rating IP 20
Temperature –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity 5%-95%, without condensation
Altitude ≤1000m; VFD will be derated if above 1000m
Impingement and oscillation Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

 

Tips: Choose between Variable Frequency Drive and Soft Starter
I would like to say that variable frequency drives (VFD) are not always the best way of saving energy. If the induction motor is running at full speed it is sometime more efficient to use a soft starter or fixed speed motor controller. Of course if the application can be slowed down then VFD is a very good solution.

If the load is required to run at full speed all the time then using a VFD is less efficient and in fact will introduce losses that a soft starter would not. We approach the market that there are different products for different jobs, sometimes VFDs are the best solution and sometimes soft starters are, it all depends on what the client wants to achieve.

Write your own review for 60 hp (45 kW) VFD, 3 Phase 240V, 380V, 480V