Affordable 180 hp soft starter, 132 kW three phase 240v, 415v, 480v, 690v softstarter, control AC induction motor in soft start & soft stop, direct sale by manufacturer.
Free shipping
Delivery date: 6 - 12 Days
-
-
-
-
$1,469.00
$1,299.31
180 hp motor soft starter, 132 kW three phase 240v, 415v, 480v, 690v AC motor starter.
| Model |
GS2-132 (240v), GS3-132 (415v), GS4-132 (480v), GS6-132 (690v). |
| Capacity |
180 hp (132 kw) |
| Current |
264 amps at 415v/480v, 560 amps at 220v, 180 amps at 690v |
| Weight |
21 kgs |
| Dimension |
525*257*194 mm |
| Input |
Voltage |
3 phase 240v, 415v, 480v, 690v AC |
| Frequency |
50Hz/ 60Hz |
| Adaptive Motor |
Squirrel-cage three-phase asynchronous motor |
| Starting Times |
It is recommended not to exceed 20 times per hour. |
| Communication |
DB9 interface, male plug, ① is RS485+, ⑥ is RS485- |
| Control Mode |
(1) Operation panel control. (2) Operation panel + external control. (3) External control. (4) External control + COM control. (5) Operation panel + external + COM control. (6) Operation panel + COM control. (7) COM control. (8) No start or stop operation. |
| Start Mode |
(1) Current-limiting to start. (2) Voltage ramp to start. (3) Torque control + current-limiting to start. (4) Torque control + voltage ramp to start. (5) Current ramp to start. (6) Voltage current-limiting double closed-loop start. |
| Stop Mode |
(1) Soft stop. (2) Free stop. |
| Protective Function |
(1) Open loop protection for external instantaneous stop terminals. (2) Over-heat protection for soft starter. (3) Protection for too long starting time. (4) Input open phase protection. (5) Output open phase protection. (6) Unbalanced three-phase protection. (7) Starting over current protection. (8) Running overload protection. (9) Under voltage protection for power voltage. (10) Overvoltage protection for power voltage. (11) Protection for fault parameter setting of the soft starter. (12) Load short circuit protection. (13) Auto restart or incorrect wiring protection. (14) Incorrect wiring protection of external control stop terminals. |
| Ambient |
Place to be used |
Indoor location with good ventilation free from corrosive gas and conductive dust. |
| Altitude |
Below 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M. |
| Temperature |
-30 +55 oC |
| Humidity |
90%RH without dew condensation. |
| Vibration |
<0.5G |
| Structure |
Enclosure |
IP 20 |
| Cooling |
Natural wind cooling. |
Existing reviews
This 180HP soft starter runs very smoothly and successfully solves the problem of current shock during equipment startup.
By
Mckeon
on 17/12, 2024
Was this review helpful?
Yes /
No
(0/0)
The operation is super easy, just follow the instructions and you’re good to go. It’s saved me a lot of time. Been using it for a few months now and there haven’t been any issues, seems pretty good.
By
Djeeta
on 12/08, 2024
Was this review helpful?
Yes /
No
(0/0)